This table defines the air pressure ranges necessary to provide CC20 Series respirators with a volume of air that falls within the required range of
6-15 cfm or 170-425 lpm according to U.S. Government regulations (42 CFR, Part 84, Subpart J, 84.150, Table 8).
1 2 3 4 5 6
Flow Control Valve/ Air Supply Air Supply Maximum Required
Air Source Climate Control Device Hose Hose Length Number of Pressure Range
(feet) Hose Sections (psig air)
Stationary F30, F30B, F30S, F31, F32, V10 25 1 14-15
or Portable F33, F34 50 2 15-18
Air Compressor 100 3 19-24
150 4 23-29
200 5 25-34
250-300 5 31-39
F40, F40B, F40S, F41, F42, V10 25 1 22-25
F43, F44 50 2 24-27
100 3 27-32
150 4 30-37
200 5 33-40
NEW 250-300 5 38-45
V5 25 1 22-26
50 2 25-30
AC100030, AC100030B, V10 25-50 2 55-65
AC100030S, AC100031, 75-150 3 60-70
AC100032, AC100033, 175-300 5 65-75
AC100034
V5 25 1 55-65
50 1 56-69
DC5040, DC5040B, DC5040S V10 50 2 52-54
DC5041, DC5042, DC5043, 100 3 59-63
DC5044 150 3 68-72
200 3 80-84
250 3 85-92
NEW 300 5 90-98
V5 25 1 53-57
50 2 67-71
HC240030, HC240030B, V10 25 1 59-61
HC240030S, HC240031, 50 2 63-65
HC240032, HC240033, 100 3 68-70
HC240034 150 4 73-75
200 4 77-79
250 5 80-82
300 5 84-86
V5 25 1 65-66
50 1 68-69
Bullard F35, F35B, F35S V20 50 1 4-6
Free-Air
®
100 2 6-8
Pumps 200 2 10-15
300 3 13-18
NEW Frigitron 2000 V20 50 1 16-22
Frigitron 2000B 100 2 18-25
Frigitron 2000S 200 2 22-30
300 3 25-34